Power rating |
180 W |
Efficiency |
85% TYP. (At 100 VAC input)
88% TYP. (At 200 VAC input) |
Rated input voltage |
100 to 240 VAC |
Allowable-input voltage variable range |
85 to 264 VAC
80 to 370 VDC |
Note at DC input |
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). |
Frequency |
50/60 Hz (47 to 63 Hz Single-phase) |
Rated input current |
2.2 A TYP. (At 100 VAC input)
1.1 A TYP. (At 200 VAC input) |
Power factor |
0.9 Min. |
Harmonic Current |
EN61000-3-2 |
Leakage current |
0.5 mA Max. (At 100 VAC input)
1.0 mA Max. (At 200 VAC input) |
Inrush current |
14 A TYP. (At 100 VAC input (For cold start at 25 CEL))
28 A TYP. (At 200 VAC input (For cold start at 25 CEL)) |
Rated output voltage |
24 VDC |
Output voltage variable range |
-10 to +15% (With V. ADJ)
(The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.) |
Ripple |
2%(p-p) Max. (Under the rated I/O conditions.)
50 mV Max. (Under the rated I/O conditions.) |
Static input variation influence |
0.5% Max. (At 85 to 264 VAC input, 100% load) |
Static load variation influence |
1.5% Max. (At rated input, 0 to 100% load) |
Ambient temperature variation influence |
0.05 %/CEL Max. |
Rated output current |
7.5 A |
Start up time |
570 ms TYP. (100 VAC input)
470 ms TYP. (200 VAC input) |
Hold time |
58 ms TYP. (100 VAC input)
62 ms TYP. (200 VAC input) |
Overload protection |
105% to 160% of the rated output current
Inverted L voltage drop, Automatic reset |
Overvoltage protection |
Operated at 115 to 150 % of the rated output voltage, Shut-off
Resetting: Reset the power by turning it back (OFF time: at least 3 min) |
Overheat protection |
No |
Maintenance forecast monitor output |
No |
Total run time monitor output |
No |
Undervoltage alarm output |
No |
Power failure alarm output |
No |
Parallel operation |
No (However, backup operation is possible; external diodes required.) |
Series operation |
Yes (Up to 2 Power Supplies with external diode) |
Remote sensing function |
No |
Applicable standard (UL) |
Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition) |
Applicable standard (CSA) |
Standard No.: cUL: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1 |
Applicable standard (EN) |
Standard No.: EN50178, EN60950-1 |
Applicable standard (EC Directive (EMI)) |
EMI: EN61204-3 Class B
Emission Enclosure: Conforms to EN55011 Group 1 Class B
Emission AC mains: Conforms to EN55011 Group 1 Class B and based on FCC Class A
EMS: EN61204-3 High severity levels |
Applicable standard(VDE) |
Standard No.: VDE0160, VDE0805 Teil 1 File number: |
Applicable standard(SEMI) |
F47-0200 (200 VAC input) |
Ambient temperature |
Operating: -10 to 60 CEL
Storage: -25 to 65 CEL
(with no icing or condensation) |
Ambient humidity |
Operating: 25 to 85%
Storage: 25 to 90%
(With no icing or condensation) |
Dielectric strength |
Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)
Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)
Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 30 mA)
Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA) |
Insulation resistance |
Between all outputs/alarm outputs and all inputs/PE terminals: 100 MOhm Min. (at 500 VDC) |
Vibration resistance |
10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
Shock resistance |
150 m/s**2, in each 6 directions 3 times |
Output indicator |
Yes (color: green) |
Heat radiation |
Natural air-cooling |
Construction |
Covered type |
Terminal type |
Screw terminal |
Mounting type |
DIN Rail mounting type |
Weight |
850 g Max. |