Product characteristics |
|
Electronic level sensor |
|
Connector |
|
Probe length: L = 728 mm |
|
2 switching outputs |
|
7-segment LED display |
Application |
|
Application |
|
hydrous coolants
mineral oils (dielectric constant < 3)
water, media similar to water
cannot be used for media with separation layers (oil + water; oil/metal layer)
cannot be used for acids and alkalis |
|
Dielectric constant medium |
|
> 2 |
|
Medium temperature oil [?C] |
|
0...65 |
|
Medium temperature water and hydrous media [?C] |
|
0...55 **) |
|
Medium temperature coolant emulsions [?C] |
|
0...55 **) |
|
Medium temperature [?C] |
|
0...35 (LK4024 + E43102: 0...55) **) |
|
Maximum speed of the change of level [mm/s] |
|
300 |
Electrical data |
|
Electrical design |
|
DC PNP |
|
Operating voltage [V] |
|
12...30 DC |
|
Current consumption [mA] |
|
< 80 |
|
Protection class |
|
III |
|
Reverse polarity protection |
|
yes |
Outputs |
|
Output |
|
2 switching outputs |
|
Output function |
|
2 x normally open / closed programmable |
|
Current rating [mA] |
|
200 |
|
Voltage drop [V] |
|
< 2.5 |
|
Short-circuit protection |
|
pulsed |
|
Overload protection |
|
yes |
Measuring / setting range |
|
Probe length L [mm] |
|
728 |
|
Active range A [mm] |
|
585 |
|
Inactive range I1 / I2 [mm] |
|
102 / 40 |
|
Setting range |
|
Set point, SP [mm] |
|
60...610 |
|
Reset point, rP [mm] |
|
50...600 |
|
in steps of [mm] |
|
10 |
|
Hysteresis [mm] |
|
10 |
Accuracy / deviations |
|
Deviations (% of value of measuring range) |
|
Switch point accuracy |
|
? 5 |
|
Repeatability |
|
? 2 |
Reaction times |
|
Power-on delay time [s] |
|
3 |
Software / programming |
|
Adjustment of the switch point |
|
Programming button |
Environment |
|
Ambient temperature [?C] |
|
0...60 |
|
Storage temperature [?C] |
|
-25...80 |
|
Maximum vessel pressure [bar] |
|
0.5 (when mounted with mounting accessories E43001 - E43007) |
|
Protection |
|
IP 67 |
Tests / approvals |
|
EMC |
|
|
EN 61000-4-2 ESD: |
4 kV CD / 8 kV AD |
|
EN 61000-4-3 HF radiated: |
10 V/m |
|
EN 61000-4-4 Burst: |
2 kV |
|
EN 61000-4-5 Surge: |
500 V / 1 kV |
|
EN 61000-4-6 HF conducted: |
10 V |
|
|
Shock resistance |
|
|
DIN EN 60068-2-29: |
12 g (11 ms) |
|
|
Vibration resistance |
|
|
DIN EN 60068-2-6: |
2.5 g (10...2000 Hz) |
|
|
MTTF [Years] |
|
285 |
Mechanical data |
|
Materials (wetted parts) |
|
PP (polypropylene) |
|
Housing materials |
|
EPDM/X (Santoprene); FPM (Viton); brass Optalloy-plated; NBR (Buna N); PA; PBT (Pocan); PC (Makrolon); PP (polypropylene) |
|
Weight [kg] |
|
0.702 |
Displays / operating elements |
|
Display |
|
|
Switching status |
2 x LED red |
|
Measured values |
7-segment LED display |
|
Programming |
7-segment LED display |
|
Electrical connection |
|
Connection |
|
M12 connector; gold-plated contacts |
Wiring
Programming of the output function:
Hno = hysteresis / normally open
Hnc = hysteresis / normally closed
Fno = window function / normally open
Fnc = window function / normally closed
Complementary outputs:
output 1: = Hno, output 2: = Hnc
(with the same SP / rP) |
 |
|
|
Remarks |
|
Remarks |
|
|
**) for water and hydrous media with temperatures > 35 ?C install the unit into a climatic tube |
|
(order no. E43102) |
|
|
Pack quantity [piece] |
|
1 |
|
ifm electronic gmbh • Friedrichstra?e 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — GB — LK7024 — 14.11.2012 |